Error Correction Coding Error
GCR_ECC_ER
[0x0064]
Bits
Field
Access
Reset
Description
9
ic1eccerr
R/W1C
0
Instruction Cache 1 ECC Error
Write to 1 to clear the flag.
0: No error
1: Error
8
ic0eccerr
R/W1C
0
Instruction Cache 0 ECC Error
Write to 1 to clear the flag.
0: No error
1: Error
7
-
RO
0
Reserved
6
sysram6eccerr
RO
0
System RAM6 ECC Error
Write to 1 to clear the flag.
0: No error
1: Error
5
sysram5eccerr
R/W1C
0
System RAM5 ECC Error
Write to 1 to clear the flag.
0: No error
1: Error
4
sysram4eccerr
R/W1C
0
System RAM4 ECC Error
Write to 1 to clear the flag.
0: No error
1: Error
3
sysram3eccerr
R/W1C
0
System RAM3 ECC Error
Write to 1 to clear the flag.
0: No error
1: Error
2
sysram2eccerr
R/W1C
0
System RAM2 ECC Error
Write to 1 to clear the flag.
0: No error
1: Error
1
sysram1eccerr
R/W1C
0
System RAM1 ECC Error
Write to 1 to clear the flag.
0: No error
1: Error
0
sysram0eccerr
R/W1C
0
System RAM0 ECC Error
Write to 1 to clear the flag.
0: No error
1: Error
Table 4-69: Error Correction Not Double Error Detected Register
Error Correction Coding Not Double Error Detected
GCR_ECC_NDED
[0x0068]
Bits
Field
Access
Reset
Description
31:13
-
RO
0
Reserved
12
fl1eccnded
R/W1C
1
Flash1 Not Double ECC Error Detected
When cleared, indicates that there is a single correctable error in the Flash1
bank. Write to 1 to clear the flag.
0: No error
1: Error

Table of Contents