EasyManua.ls Logo

Maxim Integrated MAX32665 - Table 8-79: SDHC Normal Interrupt Signal Enable Register

Maxim Integrated MAX32665
457 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAX32665-MAX32668 User Guide
Maxim Integrated Page 209 of 457
Error Interrupt Status Enable Register
SDHC_ER_INT_EN
[0x0036]
Bits
Name
Access
Reset
Description
8
auto_cmd_12
R/W
0
Auto CMD12 Error Status Interrupt Enable
1: Enabled
0: Disabled
7
-
R/W
0
Reserved for Future Use
Do not modify this field.
6
data_end_bit
R/W
0
Data End Bit Error Status Interrupt Enable
1: Enabled
0: Disabled
5
data_crc
R/W
0
Data CRC Error Status Interrupt Enable
1: Enabled
0: Disabled
4
data_to
R/W
0
Data Timeout Error Status Interrupt Enable
1: Enabled
0: Disabled
3
cmd_idx
R/W
0
Command Index Error Status Interrupt Enable
1: Enabled
0: Disabled
2
cmd_end_bit
R/W
0
Command End Bit Error Status Interrupt Enable
1: Enabled
0: Disabled
1
cmd_crc
R/W
0
Command CRC Error Status Interrupt Enable
1: Enabled
0: Disabled
0
cmd_to
R/W
0
Command Timeout Error Status Interrupt Enable
1: Enabled
0: Disabled
Table 8-79: SDHC Normal Interrupt Signal Enable Register
Normal Interrupt Signal Enable Register
SDHC_INT_SIGNAL
[0x0038]
Bits
Name
Access
Reset
Description
15:13
-
R/W
0
Reserved for Future Use
Do not modify this field.
12
retuning
R/W
0
Re-Tuning Event Signal Enable
1: Enabled
0: Disabled
11:9
-
R/W
0
Reserved for Future Use
Do not modify this field.
8
card_int
R/W
0
Card Interrupt Signal Enable
1: Enabled
0: Disabled
7
card_removal
R/W
0
Card Removal Signal Enable
1: Enabled
0: Disabled

Table of Contents