EasyManuals Logo

Maxim Integrated MAX32665 User Manual

Maxim Integrated MAX32665
457 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #243 background imageLoading...
Page #243 background image
MAX32665-MAX32668 User Guide
Maxim Integrated Page 243 of 457
Table 10-3: CRC Control Register
CRC Control Register
CRC_CTRL
[0x000C]
Bits
Name
Access
Reset
Description
31:2
-
R/W
0
Reserved for Future Use
Do not modify this field.
1
msb
R/W
0
MSB Select
Set the order of calculating the CRC on the input data.
0: LSB data first.
1: MSB data first.
0
crc_en
R/W
0
CRC Enable
Enable the CRC function.
0: CRC function disabled.
1: CRC function enable.
Table 10-4: CRC DMA Source Register
CRC DMA Source Register
CRC_DMA_SRC
[0x0010]
Bits
Name
Access
Reset
Description
31:0
src_addr
R/W
0
DMA Source Address
Set this field to the address of the DMA source input data.
Table 10-5: CRC DMA Destination Register
CRC DMA Destination Register
CRC_DMA_DST
[0x0014]
Bits
Name
Access
Reset
Description
31:0
dst_addr
R/W
0
DMA Destination Address
Set this field to the address for the CRC DMA output data.
Table 10-6: CRC DMA Count Register
CRC DMA Count Register
CRC_DMA_CNT
[0x0018]
Bits
Name
Access
Reset
Description
31:0
count
R/W
0
DMA Byte Count
Set this field to the number of bytes of input data to the CRC engine.

Table of Contents