MAX32665-MAX32668 User Guide
Maxim Integrated Page 45 of 457
Error Correction Coding Error
GCR_ECC_ER
[0x0064]
Bits
Field
Access
Reset
Description
12
fl1eccerr
R/W1C
0
ECC Flash1 Error
Indicates an ECC error in the Flash1 bank. Write to 1 to clear.
0: No Error
1: Error
11
fl0eccerr
R/W1C
0
ECC Flash0 Error
Indicates an ECC error in the Flash0 bank. Write to 1 to clear.
0: No Error
1: Error
10
icspixfeccerr
R/W1C
0
ECC SPIXF Instruction Cache Error
Indicates an ECC error in SPIXF Instruction Cache. Write to 1 to clear.
0: No Error
1: Error
9
ic1eccerr
R/W1C
0
ECC Instruction Cache 1 Error
Indicates an ECC error in Instruction Cache 1. Write to 1 to clear.
0: No Error
1: Error
8
ic0eccerr
R/W1C
o
ECC Instruction Cache 0 Error
Indicates an ECC error in Instruction Cache 0. Write to 1 to clear.
0: No Error
1: Error
7:6
-
RO
0
Reserved for Future Use
Do not modify this field.
5
sysram5eccerr
R/W1C
0
ECC Sysram5 Error
Indicates an ECC error in the Sysram5 block. Write to 1 to clear.
0: No Error
1: Error
4
sysram4eccerr
R/W1C
0
ECC Sysram4 Error
Indicates an ECC error in the Sysram4 block. Write to 1 to clear.
0: No Error
1: Error
3
sysram3eccerr
R/W1C
0
ECC Sysram3 Error
Indicates an ECC error in the Sysram3 block. Write to 1 to clear.
0: No Error
1: Error
2
sysram2eccerr
R/W1C
0
ECC Sysram2 Error
Indicates an ECC error in the Sysram2 block. Write to 1 to clear.
0: No Error
1: Error
1
sysram1eccerr
R/W1C
0
ECC Sysram1 Error
Indicates an ECC error in the Sysram1 block. Write to 1 to clear.
0: No Error
1: Error
0
sysram0eccerr
R/W1C
0
ECC Sysram00 Error
Indicates an ECC error in the Sysram0 block. Write to 1 to clear.
0: No Error
1: Error