EasyManuals Logo

Maxim Integrated MAX32665 User Manual

Maxim Integrated MAX32665
457 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
MAX32665-MAX32668 User Guide
Maxim Integrated Page 88 of 457
Reset 0
GCR_RST0
[0x0004]
Bits
Field
Access
Reset
Description
30
periph_rst
R/W
0
Peripheral Reset
Write 1 to reset.
0: Not in reset
1: Reset in progress.
Note: Watchdog Timers, GPIO Ports, the AoD, RAM Retention and the General Control
Registers (GCR) are unaffected.
29
soft_rst
R/W
0
Soft Reset
Write 1 to reset.
0: Not in reset
1: Reset in progress.
28
uart2
R/W
0
UART2 Reset
Write 1 to reset.
0: Not in reset.
1: Reset in progress.
27
dma1
R/W
0
DMA1 Reset
Write 1 to reset.
0: Not in reset
1: Reset in progress.
26
adc
R/W
0
ADC Reset
Write 1 to reset.
0: Not in reset
1: Reset in progress.
25:24
-
R/W
0
Reserved
Do not modify this field.
23
usb
R/W
0
USB Reset
Write 1 to reset.
0: Not in reset
1: Reset in progress..
22
smphr
R/W
0
Semaphore Block Reset
Write 1 to reset.
0: Not in reset
1: Reset in progress.
21:19
-
R/W
-
Reserved
Do not modify this field.
18
crypto
R/W
0
Cryptographic Reset
Write 1 to reset. This resets the AES block, SHA block, and DES block.
0: Not in reset
1: Reset in progress.
17
rtc
R/W
0
RTC Reset
Write 1 to reset.
0: Not in reset
1: Reset in progress.
16
i2c0
R/W
0
I2C0 Reset
Write 1 to reset.
0: Not in reset
1: Reset in progress.