Peripheral Clock Disable 1
GCR_PCLK_DIS1
[0x0048]
Bits
Field
Access
Reset
Description
13
ow
R/W
1
One-Wire Clock Disable
Disabling the clock disables functionality while also saving power. Associated register
states are retained but read and write access is blocked.
0: Enabled.
1: Disabled.
12
icachexipf
R/W
1
SFCC Flash Clock Disable
Disabling the clock disables functionality while also saving power. Associated register
states are retained but read and write access is blocked.
0: Enabled.
1: Disabled.
11
-
R/W
1
Reserved
Do not modify this field.
10
sdhc
R/W
1
SDHC Controller Clock Disable
Disabling the clock disables functionality while also saving power. Associated register
states are retained but read and write access is blocked.
0: Enabled.
1: Disabled.
9
smphr
R/W
1
Semaphore Block Clock Disable
Disabling the clock disables functionality while also saving power. Associated register
states are retained but read and write access is blocked.
0: Enabled.
1: Disabled.
8
sdma
R/W
1
Bluetooth Hardware Accelerator Clock Disable
Disabling the clock disables functionality while also saving power. Associated register
states are retained but read and write access is blocked.
0: Enabled.
1: Disabled.
7
scache
R/W
1
SRCC Cache Clock Disable
Disabling the clock disables functionality while also saving power. Associated register
states are retained but read and write access is blocked.
0: Enabled.
1: Disabled.
6:3
-
R/W
1
Reserved
Do not modify this field.
2
trng
R/W
1
TRNG Clock Disable
Disabling the clock disables functionality while also saving power. Associated register
states are retained but read and write access is blocked.
0: Enabled.
1: Disabled.
1
uart2
R/W
1
UART2 Clock Disable
Disabling the clock disables functionality while also saving power. Associated register
states are retained but read and write access is blocked.
0: Enabled.
1: Disabled.