B-9
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
December 2006
Appendix B Hardware Specifications
B.3.3 AIC-I Card Specifications
Normal operation: –40.5 to –56.7 V (in –48 VDC systems)
Undervoltage: Major alarm
Overvoltage: Major alarm
Environmental
Operating temperature: –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius)
Operating humidity: 5 to 95 percent, noncondensing
Power consumption: 26.00 W, 0.54 A at –48 V, 88.8 BTU/hr
Dimensions
Height: 12.650 in. (321.3 mm)
Width: 0.716 in. (18.2 mm)
Depth: 9.000 in. (228.6 mm)
Depth with backplane connector: 9.250 in. (235 mm)
Weight not including clam shell: 1.5 lb (0.7 kg)
B.3.3 AIC-I Card Specifications
The AIC-I card has the following specifications:
Alarm inputs
Number of inputs: 12 without AEP, 32 with AEP
Opto-coupler isolated
Label customer provisionable
Severity customer provisionable
Common 32 V output for all alarm inputs
Each input limited to 2 mA
Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP
Alarm outputs
Number of outputs: 4 (user configurable as inputs) without AEP, 16 with AEP
Switched by opto MOS (metal oxide semiconductor)
Triggered by definable alarm condition
Maximum allowed open circuit voltage: 60 VDC
Maximum allowed closed circuit current: 100 mA
Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP
Express orderwire/local orderwire (EOW/LOW)
ITU-T G.711, ITU-T G.712, Telcordia GR-253-CORE
A-law, mu-law
Note Due to the nature of mixed coding, in a mixed-mode (A-law/mu-law) configuration, the
orderwire is not ITU-T G.712 compliant.