8-14
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 8 Manage Alarms
NTP-G66 View Alarm-Affected Circuits
Step 5 To remove the transient messages from the History window, click Delete Cleared Alarms. Transient
messages are single messages, not raise-and-clear pairs (that is, they do not have companion messages
stating that they are cleared).
Stop. You have completed this procedure.
NTP-G66 View Alarm-Affected Circuits
Step 1 Complete the “DLP-G46 Log into CTC” task on page 2-25. If you are already logged in, continue with
Step 2.
Step 2 In network, node, or card view, click the Alarms tab or Conditions tab and then right-click anywhere
in the row of an active alarm or condition.
Note The node view is the default, but you can also navigate to the Alarms tab in the network view or
card view to perform Step 2.
The Select Affected Circuit option appears on the shortcut menu.
Step 3 Left-click or right-click Select Affected Circuits.
The Circuits window appears with the affected OCHNC highlighted.
Stop. You have completed this procedure.
Purpose Use this procedure to view all optical channel network connections
(OCHNCs) and ONS 15454 circuits, if any, that are affected by an alarm
or condition.
Tools/Equipment None
Prerequisite Procedures NTP-G64 View Alarms, History, Events, and Conditions, page 8-6
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Retrieve or higher