16-22
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
April 2006
Chapter 16 Card Reference
16.3.1 MIC-A/P FMEC
• Storage of manufacturing and inventory data
For proper system operation, both the MIC-A/P and MIC-C/T/P FMECs must be installed in the
ONS 15454 ETSI shelf. Figure 16-5 shows the MIC-A/P faceplate.
Figure 16-5 MIC-A/P Faceplate
Figure 16-6 shows a block diagram of the MIC-A/P.
Figure 16-6 MIC-A/P Block Diagram
Table 16-15 shows the alarm interface pinouts on the MIC-A/P DB-62 connector.
61323
MIC-A/P
ALARM
IN/OUT
CLEI CODE BARCODE
POWER RATING
BATTERY B
+
Inventory Data
(EEPROM)
61332
B
a
c
k
p
l
a
n
e
3W3
Connector
Alarms
DB62
Connector
Power
16 Alarm inputs
4 Alarm in/outputs
Table 16-15 Alarm Interface Pinouts on the MIC-A/P DB-62 Connector
Pin No. Signal Name Signal Description
1 ALMCUTOFF N Alarm cutoff, normally open ACO pair
2 ALMCUTOFF P Alarm cutoff, normally open ACO pair
3 ALMINP0 N Alarm input pair 1, reports closure on connected wires
4 ALMINP0 P Alarm input pair 1, reports closure on connected wires
5 ALMINP1 N Alarm input pair 2, reports closure on connected wires
6 ALMINP1 P Alarm input pair 2, reports closure on connected wires
7 ALMINP2 N Alarm input pair 3, reports closure on connected wires