EasyManua.ls Logo

Cisco ONS 15454 DWDM - Power Monitoring

Cisco ONS 15454 DWDM
1218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16-75
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
April 2006
Chapter 16 Card Reference
16.7.5 AD-4B-xx.x Card
Figure 16-49 AD-4B-xx.x Block Diagram
Figure 16-50 shows the AD-4B-xx.x optical module functional block diagram.
Figure 16-50 AD-4B-xx.x Optical Module Functional Block Diagram
16.7.5.1 Power Monitoring
Physical photodiodes P1 through P11, and virtual photodiode V1 monitor the power for the AD-4B-xx.x
card. The returned power level values are calibrated to the ports as shown in Table 16-46.
Optical
Module
COM RX
COM TX
124075
uP8260
processor
DC/DC
converter
EXP TX
EXP RX
FPGA
For SCL Bus
management
SCL Bus
TCC M
SCL Bus
TCC P
Power supply
Input filters
BAT A&B
Add
Rx
Drop
Tx
Channel 1
Add
Rx
Drop
Tx
Channel 2
Add
Rx
Drop
Tx
Channel 3
Add
Rx
Drop
Tx
Channel 4
Virtual photodiode
COM
RX
TX
B30.3 or B46.1
RX
Control
Control
interface
Physical photodiode
Variable optical attenuator
V
V1
EXP
RX
EXP
TX
COM
TX
TX
B34.2 or B50.1
RX TX
B38.1 or B54.1
RX TX RX
B42.1 or B58.1
98308
P1
P
P2 P3 P4 P9
P10P12P11
P5 P6 P7 P8

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Related product manuals