EasyManua.ls Logo

Cisco ONS 15454 DWDM - DLP- G271 Verify the AD-XC-XX.X Output Common Power

Cisco ONS 15454 DWDM
1218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-48
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 4 Perform Node Acceptance Tests
DLP-G271 Verify the AD-xC-xx.x Output Common Power
DLP-G271 Verify the AD-xC-xx.x Output Common Power
Step 1 Display the AD-xC-xx.x card in card view.
Step 2 Click the Provisioning > Optical Line > Parameters tabs.
Step 3 Verify that the Output Com port Power value is greater than the default no-power value of –30 dBm.
Step 4 Return to your originating procedure (NTP).
DLP-G272 Verify the AD-xB-xx.x Output Common Power
Step 1 Display the AD-xB-xx.x card in card view.
Step 2 Click the Provisioning > Optical Line > Parameters tabs.
Step 3 Verify that the Output Com port Power value is greater than the default no-power value of –28 dBm.
Step 4 Return to your originating procedure (NTP).
Purpose This task verifies the output common power of the AD-xC-xx.x cards.
Tools/Equipment None
Prerequisite Procedures DLP-G46 Log into CTC, page 2-25
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser
Purpose This task verifies the output common power of the AD-xB-xx.x cards.
Tools/Equipment None
Prerequisite Procedures DLP-G46 Log into CTC, page 2-25
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Related product manuals