10-4
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 10 Manage the Node
DLP-G157 Disable Automatic Power Control
DLP-G157 Disable Automatic Power Control
Caution Disable APC only to perform specific troubleshooting or node provisioning tasks. Always enable APC
as soon as the tasks are completed. Leaving APC disabled can cause traffic loss.
Step 1 In node view, click the Maintenance > DWDM > APC tabs.
Step 2 Click Disable APC.
Step 3 Verify that the Enable APC button changes to Disable APC.
Step 4 Return to your originating procedure (NTP).
DLP-G158 Enable Automatic Power Control
Caution Disable APC only to perform specific troubleshooting or node provisioning tasks. Always enable APC
as soon as the tasks are completed. Leaving APC disabled can cause traffic loss.
Step 1 In node view, click the Maintenance > DWDM > APC tabs.
Step 2 Click Enable APC.
Step 3 In the confirmation dialog box, Click Yes .
Purpose This task disables the DWDM APC.
Tools/Equipment None
Prerequisite Procedures All procedures in the following chapters:
Chapter 3, “Turn Up a Node”
Chapter 6, “Turn Up Network”
DLP-G46 Log into CTC, page 2-25
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser
Purpose This task enables the DWDM APC.
Tools/Equipment None
Prerequisite Procedures All procedures in the following chapters:
Chapter 3, “Turn Up a Node”
Chapter 6, “Turn Up Network”
DLP-G46 Log into CTC, page 2-25
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser