11-22
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 11 Change DWDM Card Settings
DLP-G322 Change the OPT-BST ALS Maintenance Settings
DLP-G322 Change the OPT-BST ALS Maintenance Settings
Step 1 In node view, double-click the OPT-BST where you want to change the ALS maintenance settings.
Step 2 Click the Maintenance > ALS tabs.
Step 3 Modify any of the settings described in Table 11-13. The provisionable parameters are listed in the
options column in the table.
Purpose This task changes the ALS maintenance settings for the OPT-BST card.
Tools/Equipment None
Prerequisite Procedures DLP-G46 Log into CTC, page 2-25
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher
Table 11-13 OPT-BST Maintenance Settings
Parameter Description Options
OSRI Optical safety remote interlock. When set
to On, the OPT-BST TX output power is
shut down.
From the drop-down list, choose one
of the following:
On
Off
ALS Mode Automatic laser shutdown mode. For
OPT-BST cards, ALS provides the ability
to shut down the OPT-BST TX laser
when the OPT-BST RX detects an LOS.
ALS also enables an optical safety
mechanism at the DWDM network layer.
See the “16.8.5.13 Automatic Laser
Shutdown” section on page 16-105 for
more information.
From the drop-down list, choose one
of the following:
Disable—Deactivates ALS.
Auto Restart—(Default) ALS is
active. The power is
automatically shut down when
needed and automatically tries to
restart using a probe pulse until
the cause of the failure is
repaired.
Manual Restart
Manual Restart for Test
Recovery Pulse
Duration
(Display only) Displays the duration of
the optical power pulse that begins when
an amplifier restarts.
Recovery Pulse
Interval
(Display only) Displays the interval
between optical power pulses.
Currently
Shutdown
(Display only) Displays the current status
of the laser.
Request Laser
Restart
If checked, allows you to restart the laser
for maintenance.
Checked or unchecked