5-40
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 5 Provision Transponder and Muxponder Cards
DLP-G226 Change Line Thresholds Settings for MXP_2.5G_10G and MXP_2.5G_10E Cards
Note You must modify Near End, and Far End independently; 15 Min and 1 Day independently; and Line or
Multiplex Section and Section or Regeneration Section independently. To do so, choose the appropriate
radio button and click Refresh.
Note In Table 5-20, some parameter tabs or selections do not always apply to both the MXP_2.5G_10G and
the MXP_2.5G_10E card. If the tabs or selections do not apply, they do not appear in CTC.
Table 5-20 MXP_2.5G_10G and MXP_2.5G_10E Card Line Threshold Settings
Parameter Description ONS 15454 Options ONS 15454 SDH Options
Port (Display only)
Port number
• 1-1 (OC192)
• 2 (Trunk)
• 1-1 (STM64)
• 2 (Trunk)
CV Coding
violations
Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Line or Section (near end only)
Choose an option in each category and click
Refresh.
Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and click
Refresh.
ES Errored
seconds
Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Line or Section (near end only)
Choose an option in each category and click
Refresh.
Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and click
Refresh.
SES Severely
errored
seconds
Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Line or Section (near end only)
Choose an option in each category and click
Refresh.
Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and click
Refresh.
SEFS (Section only)
Severely
errored
framing
seconds
Numeric. Can be set for Far End for 15-minute
or one-day intervals for Section only. Choose
an interval option and click Refresh.
Numeric. Can be set for Far End for 15-minute
or one-day intervals for Regeneration Section
only. Choose an interval option and click
Refresh.