D-97
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
August 2005
Appendix D Network Element Defaults
D.3.1 ETSI Card Default Settings
TXPP-MR-2_5G.config.client.ppmSlotAssignment UNASSIGNE
D
UNASSIGNED, PPM (1 Port)
TXPP-MR-2_5G.config.client.SDBER 1E-7 1E-5, 1E-6, 1E-7, 1E-8, 1E-9
TXPP-MR-2_5G.config.client.SFBER 1E-4 1E-3, 1E-4, 1E-5
TXPP-MR-2_5G.config.client.TerminationMode Transparent
• Transparent, Regeneration
Section, Multiplex Section
when ppmPortAssignment
is UNASSIGNED,
STM1_PORT,
STM4_PORT,
STM16_PORT
• Transparent when
ppmPortAssignment is
STM1_PORT,
STM4_PORT,
STM16_PORT,
ONE_GE_PORT,
ESCON_PORT,
DV6000_PORT,
SDI_D1_VIDEO_PORT,
HDTV_PORT,
PASS_THRU_PORT,
ETR_CLO_PORT, ISC
compat, FC1G_PORT,
FC2G_PORT,
FICON1G_PORT,
FICON2G_PORT, ISC peer
TXPP-MR-2_5G.config.trunk.AINSSoakTime 08:00
(hours:mins)
00:00, 00:15, 00:30 .. 48:00
TXPP-MR-2_5G.config.trunk.AlsMode Disabled Disabled, Auto Restart, Manual
Restart, Manual Restart for Test
TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration 40.0 (seconds)
• 2.0, 2.1, 2.2 .. 100.0 when
AlsMode is Disabled, Auto
Restart, Manual Restart
• 80.0, 80.1, 80.2 .. 100.0
when AlsMode is Manual
Restart for Test
TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval 100 (seconds) 60–300
TXPP-MR-2_5G.config.trunk.SDBER 1E-7 1E-5, 1E-6, 1E-7, 1E-8, 1E-9
TXPP-MR-2_5G.config.trunk.SFBER 1E-4 1E-3, 1E-4, 1E-5
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias 90.0 (%) 0.0, 0.1, 0.2 .. 100.0
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower 3.0 (dBm) LowRxPower, LowRxPower +
0.1, LowRxPower + 0.2 .. 30.0
Table D-20 TXPP-MR-2.5G Card Default Settings (ETSI) (continued)
Default Name Default Value Default Domain