NTP-G34 Install Fiber-Optic Cables on DWDM Cards and DCUs
Warning
Blank faceplates (filler panels) serve three important functions: they prevent exposure to hazardous
voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might
disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate
the system unless all cards and faceplates are in place.
Statement 156
Caution Always use the supplied electrostatic discharge (ESD) wristband when working with a powered
ONS 15454. Plug the wristband cable into the ESD jack located on the lower right outside edge of the
shelf assembly and ensure the shelf assembly is properly grounded.
Step 1 Open the card ejectors.
Step 2 Slide the card along the guide rails into the correct slot.
Step 3 Close the ejectors.
Step 4 Repeat for any remaining unused card slots.
Stop. You have completed this procedure.
NTP-G34 Install Fiber-Optic Cables on DWDM Cards and DCUs
Warning
Class I (CDRH) and Class 1M (IEC) laser products.
Statement 1055
Note Complies with the US Federal Drug Administration Code of Federal Regulations Title 21, Sections
1040.10 and 1040.11, except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.
Note In this procedure, you will generally connect fibers in an east-to-west or west-to-east pattern. “West”
refers to cards and ports in Slots 1 through 8. “East” refers to cards and ports installed in Slots 10
through 17.
Purpose This procedure installs the fiber-optic cables to DWDM cards and
dispersion compensating units.
Tools/Equipment Fiber-optic cables
Cisco MetroPlanner Internal Connections table
Prerequisite Procedures NTP-G30 Install the DWDM Cards, page 3-39
NTP-G31 Install the DWDM Dispersion Compensating Units, page 3-41
(as applicable)
NTP-G139 Verify Cisco MetroPlanner Reports and Files, page 3-3
Required/As Needed As needed
Onsite/Remote Onsite