Chapter 1 Install the Shelf and Common Control Cards
DLP-G22 Install LAN Wires on the MIC-C/T/P (ETSI Only)
DLP-G22 Install LAN Wires on the MIC-C/T/P (ETSI Only)
Note Rather than using the LAN connection port on the MIC-C/T/P, you can use the LAN connection port on
the TCC2/TCC2P card if preferred. Use either the MIC-C/T/P connection or the TCC2/TCC2P card
connection. You cannot use the LAN connection port on the MIC-C/T/P and the LAN connection port
on the TCC2/TCC2P card simultaneously; however, it is possible for you to make a direct connection
from a computer to the LAN connection port on the TCC2/TCC2P card while the LAN connection port
on the MIC-C/T/P is in use as long as the computer connected directly to the TCC2/TCC2P card is not
connected to a LAN.
Step 1 Using 0.51 mm² or 0.64 mm² (#22 or #24 AWG) wire or CAT-5 UTP Ethernet cable, connect the wires
to the RJ-45 connector according to Table 1-5.
Purpose This task installs the LAN wires on the ONS 15454 ETSI MIC-C/T/P.
Tools/Equipment Standard CAT-5 UTP Ethernet cable (straight-through for data terminating
equipment [DTE] or cross-over for data circuit-terminating equipment
[DCE])
or
RJ-45 connector
Crimping tool for RJ-45 connector
0.51 mm² or 0.64 mm² (#22 or #24 AWG) wire, preferably CAT-5 UTP
Prerequisite Procedures NTP-G6 Install the MIC-A/P and MIC-T/C/P FMECs (ETSI Only), page
1-28
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None
Table 1-5 LAN Pin Assignments
LAN RJ-45 Pin RJ-45 Pin Function
LAN 1
Connecting to DCE
1
(a hub or switch)
Cross-over Ethernet cable
13PNMSRX+
white/green
26PNMSRX–
green
31PNMSTX
white/orange
44—
55—
6 2 PNMSTX–
orange
77—
88—