Loading...
13-43
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 13 Maintain the Node
NTP-G136 Import Network Element Defaults
Note Changing some NE defaults can cause CTC disconnection or a reboot of the node in order for
the default to take effect. Before you change a default, view the Side Effects column of the
Defaults editor (right-click a column header and select Show Column > Side Effects) and be
prepared for the occurrence of any side effects listed for that default.
Stop. You have completed this procedure.
NTP-G136 Import Network Element Defaults
Note For a list of NE defaults, see Appendix D, “Network Element Defaults.
Step 1 Complete the “DLP-G46 Log into CTC” task on page 2-25 at the node where you want to import NE
defaults.
Step 2 Click the Provisioning > Defaults tabs.
Step 3 Click Import.
Step 4 If the correct file name and location of the desired file do not appear in the Import Defaults from File
dialog box, click Browse and browse to the file that you are importing.
Step 5 When the correct file name and location appear in the dialog box, click OK. If you are importing the
factory defaults, the correct file name is 15454-defaults.txt for ANSI shelves and 15454SDH-defaults.txt
for ETSI shelves.
A pencil icon will appear next to any default value that will be changed as a result of importing the new
defaults file.
Step 6 Click Apply.
Step 7 If the imported file fails to pass all edits, the problem field shows the first encountered problem default
value that must be fixed. Change the problem default value and click Apply. Repeat until the imported
file passes all edits successfully.
Step 8 If you are modifying node-level defaults, a dialog box appears telling you that defaults were successfully
applied to the node. Click Ye s.
Step 9 If you are modifying the IIOP Listener Port setting, a dialog box appears warning you that the node will
reboot and asks if you want to continue. Click Ye s.
Purpose This procedure imports the NE defaults using the NE Defaults editor. The
defaults can either be imported from the CTC software CD (factory
defaults) or from a customized file exported and saved from a node.
Tools/Equipment None
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Related product manuals