Chapter 5 Provision Transponder and Muxponder Cards
DLP-G278 Provision the Optical Line Rate
DLP-G278 Provision the Optical Line Rate
Step 1 In node view, double-click the TXP or MXP card where you want to provision PPM ports. If the data
rate you are provisioning is DV-6000, HDTV, ESCON, SDI/D1 Video, ISC-3, or ETR_CLO, complete
the following steps. Otherwise, continue with Step 2.
a. Click the Provisioning > OTN > OTN Lines tabs.
b. In the G.709 OTN field, choose Disable.
c. In the FEC field, choose Disable.
d. Click Apply.
Step 2 Click the Provisioning > Pluggable Port Modules tabs.
Step 3 In the Pluggable Ports area, click Create. The Create Port dialog box appears.
Step 4 In the Create Port dialog box, complete the following:
• Port—Choose the PPM number and port number from the drop-down list. The first number indicates
the PPM and the second number indicates the port number on the PPM. For example, the first PPM
with one port displays as 1-1 and the second PPM with one port displays as 2-1. The PPM number
can be 1 to 4, but the port number is always 1.
• Port Type—Choose the type of port from the drop-down list. The port type list displays the
supported port rates on your PPM. See Table 5-1 for definitions of the supported rates on the TXP
or MXP card.
Step 5 Click OK. The row on the Pluggable Ports area turns light blue until the actual SFP is installed, and then
the row turns white.
Step 6 Repeat Steps 3 through 5 to configure the port rates as needed.
Purpose This task provisions the line rate on a multirate PPM. Single-rate PPMs do
not need to be provisioned.
Tools/Equipment None
Prerequisite Procedures DLP-G277 Provision a Multirate PPM, page 5-3
DLP-G274 Verify Topologies for ETR_CLO and ISC Services, page 5-4,
if you are provisioning an ETR_CLO service.
DLP-G46 Log into CTC, page 2-25
Required/As Needed Required
Onsite/Remote Onsite or remote
Security Level Provisioning or higher