5-41
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 5 Provision Transponder and Muxponder Cards
DLP-G303 Provision the MXP_2.5G_10G and MXP_2.5G_10E Trunk Port Alarm and TCA Thresholds
Step 4 Click Apply.
Step 5 Return to your originating procedure (NTP).
DLP-G303 Provision the MXP_2.5G_10G and MXP_2.5G_10E Trunk Port Alarm
and TCA Thresholds
Step 1 In node view, double-click the MXP_2.5G_10G or MXP_2.5G_10E card where you want to change the
trunk port alarm and TCA settings.
Step 2 Click the Provisioning > Optics Thresholds tabs.
Step 3 Select a 15 Min or 1 Day PM interval radio button and then click Refresh.
Note You must modify 15 Min and 1 Day independently. To do so, choose the appropriate radio button
and click Refresh.
FC Failure count Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Line or Section (near end only)
Choose an option in each category and click
Refresh.
Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and click
Refresh.
UAS Unavailable
seconds
Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Line or Section (near end only)
Choose an option in each category and click
Refresh.
Numeric. Threshold display options include:
• Direction—Near End or Far End
• Interval—15 Min (minutes) or 1 day
• Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and click
Refresh.
Purpose This task changes the MXP_2.5G_10G and MXP_2.5G_10E trunk port
alarm and TCA thresholds.
Tools/Equipment None
Prerequisite Procedures DLP-G46 Log into CTC, page 2-25
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher
Table 5-20 MXP_2.5G_10G and MXP_2.5G_10E Card Line Threshold Settings (continued)
Parameter Description ONS 15454 Options ONS 15454 SDH Options