Before You Begin
9. NTP-G9 Install the Alarm Expansion Panel (ANSI Only), page 1-44—Complete this procedure if
you are planning to install the Alarm Interface Controller–International (AIC-I) card and want to
increase the number of alarm contacts provided by the AIC-I card.
10. NTP-G10 Attach Wires to Alarm, Timing, LAN, and Craft Pin Connections, page 1-47—Complete
as needed to set up wire-wrap pin connections.
11. NTP-G11 Install an External Wire-Wrap Panel on the AEP (ANSI Only), page 1-58 —Complete
this procedure to connect an external wire-wrap panel to the alarm expansion panel (AEP).
12. NTP-G12 Install and Close the FMEC Cover (ETSI Only), page 1-63Complete this procedure to
install the FMEC cover.
13. NTP-G13 Install the Rear Cover (ANSI Only), page 1-64—Complete this procedure as needed to
install the rear cover after you have finished servicing the backplane.
14. NTP-G14 Install DWDM Equipment, page 1-66Complete this procedure as needed to install
equipment needed for DWDM networks.
15. NTP-G15 Install the Common Control Cards, page 1-71Complete this procedure to install the
TCC2/TCC2P card and the AIC-I card.
16. NTP-G16 Perform the Shelf Installation Acceptance Test, page 1-76—Complete this procedure to
determine if you have correctly completed all other procedures in the chapter.
Warning
Installation of the equipment must comply with local and national electrical codes.
Statement 1074
Warning
This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260.
Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The
telecommunications lines must be disconnected 1) before unplugging the main power connector or 2)
while the housing is open, or both.
Statement 1043
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Warning
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement
1022
Note The ONS 15454 is suitable for mounting on concrete or other noncombustible surfaces only.
Note In this chapter, “shelf assembly” refers to the steel enclosure that holds cards and connects power, and