EasyManuals Logo

Siemens RUGGEDCOM ROX II User Manual

Siemens RUGGEDCOM ROX II
798 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Chapter 4
Device Management
RUGGEDCOM ROX II
CLI User Guide
60 Viewing the Slot Status
SLOT DETECTED MODULE STATE STRING UPTIME
START DATE TIME
---------------------------------------------------------------------------------------------------------------------------
pm1 none empty ---- N/A
2017-01-12Z 03:19:16Z
lm1 none empty ---- 0D 0hr 0min 0sec
2017-01-11Z 10:22:45Z
lm2 none empty ---- 0D 0hr 0min 0sec
2017-01-11Z 10:25:15Z
lm3 16x 10/100TX RJ45 operating Normal 1D 6hr 28min 46sec
2017-01-11Z 10:25:14Z
cm RX5000 Control Module operating Normal 1D 6hr 33min 12sec
2017-01-12Z 03:19:16Z
sm SM 8 Gigabit Layer 2 w/ 2x 10/100/1000TX RJ45 operating Normal 1D 6hr 28min 46sec
2017-01-11Z 10:25:16Z
lm4 8x 100FX SFP operating Normal 1D 6hr 28min 45sec
2017-01-11Z 10:25:13Z
lm5 none empty ---- 0D 0hr 0min 0sec
2017-01-11Z 10:22:45Z
lm6 none empty ---- 0D 0hr 0min 0sec
2017-01-11Z 10:22:45Z
pm2 Power 88-300VDC or 85-264VAC w/ screw terminal block operating Normal N/A
2017-01-12Z 03:19:16Z
em none empty ---- N/A
2017-01-12Z 03:19:16Z
This table or list provides the following information:
Parameter Description
slot Synopsis:  { { --- }{ pm1, pm2, main }{ sm, lm1, lm2, lm3, lm4, lm5, lm6, swport, eth,
serport, celport, wlanport }{ cm, em }{ trnk } }
The slot name, as marked on the silkscreen across the top of the chassis.
detected-module Synopsis:  A string 1 to 60 characters long
The installed module's type specifier.
This parameter is mandatory.
state Synopsis:  { unknown, empty, disabled, resetting, operating, failed, disconnected }
The current state of the installed module.
This parameter is mandatory.
status-string Synopsis:  A string
The runtime status of the installed module.
This parameter is mandatory.
uptime Synopsis:  A string
The total time elapsed since the start-up of the installed module.
This parameter is mandatory.
start-date Synopsis:  A string
The date on which the installed module was started up.
This parameter is mandatory.
start-time Synopsis:  A string
The time at which the installed module was started up.
This parameter is mandatory.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals