RUGGEDCOM ROX II
CLI User Guide
Chapter 13
Unicast and Multicast Routing
Managing LSP Generation 451
Parameter Description
Hello interval in seconds, ranging from 1 to 600. Default is 3.
hello-multiplier { hello-multiplier } Synopsis:  A 16-bit unsigned integer between 2 and 100
Default:  10
Multiplier for Hello holding time. Value ranges from 2 to 100. Default is 10.
psnp-interval { psnp-interval } Synopsis:  An 8-bit unsigned integer between 1 and 120
Default:  2
PSNP interval in seconds, ranging from 1 to 120. Default is 2.
4. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section13.6.7
Managing LSP Generation
IS-IS generates new Link-State Packets (LSPs) every 30 seconds by default. However, the interval can be
configured anywhere between 1 and 120 seconds.
Since the introduction of a new LSP causes other routers in the area to recalculate routes, it is recommended to
increase the interval to decrease flooding during periods of network instability, so as to reduce the load on other
routers in the area.
CONTENTS
Section13.6.7.1, “Viewing a List of LSP Generation Intervals”
Section13.6.7.2, “Adding an LSP Generation Interval”
Section13.6.7.3, “Deleting an LSP Generation Interval”
Section13.6.7.1
Viewing a List of LSP Generation Intervals
To view a list of LSP generation intervals configured for an IS-IS area, type:
show running-config routing isis area name lsp-gen-interval
Where:
name is the unique name for a routing process that belongs to a specific router.
If intervals have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config routing isis area Area_1 lsp-gen-interval | tab
ISTYPE INTERVAL
------------------------
level-1-only 60
!
!
If no intervals have been configured, add intervals as needed. For more information, refer to Section13.6.7.2,
“Adding an LSP Generation Interval”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals