284 Adding an Ethernet Trunk Port
Section8.2.4.2
Adding an Ethernet Trunk Port
To add an Ethernet trunk port, do the following:
1. Make sure the CLI is in Configuration mode.
2. Add the port by typing:
interface trunks id trunk-ports slot port
Where:
id is the ID given to the trunk
slot is the name of the module location
port is the port number (or a list of ports, if aggregated in a port trunk) for the module
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section8.2.4.3
Deleting an Ethernet Trunk Port
To delete an Ethernet trunk port, do the following:
1. Make sure the CLI is in Configuration mode.
2. Delete the port by typing:
no interface trunks id trunk-ports slot port
Where:
id is the ID given to the trunk
slot is the name of the module location
port is the port number (or a list of ports, if aggregated in a port trunk) for the module
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section8.3
Managing MAC Addresses
As part of the Layer 2 functionality, RUGGEDCOM ROX II maintains a Media Access Control (MAC) address table, a
list of unique MAC addresses for network interfaces that can communicate with the device at the data link layer.
The MAC address table can be populated manually by defining specific MAC addresses and/or dynamically. When
populated dynamically, RUGGEDCOM ROX II automatically adds the MAC addresses of network interfaces it detects
on the network. It will also remove those addresses if the address ages out or there is a link failure.
CONTENTS
Section8.3.1, “Viewing a Dynamic List of MAC Addresses”
Section8.3.2, “Purging the Dynamic MAC Address List”
Section8.3.3, “Configuring MAC Address Learning Options”
Section8.3.4, “Managing Static MAC Addresses”

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals