Chapter 3
Getting Started
Configuring a Basic Network 53
Port: 22
2. Connect to the device.
3. If the device's SSH key has not been cached to the workstation's registry, a confirmation message will appear
asking if the host is trusted. Click Yes to continue. The login prompt appears.
login as:
4. Log in to RUGGEDCOM ROX II. For more information, refer to Section2.2, “Logging In”.
Section3.2
Configuring a Basic Network
RUGGEDCOM ROX II has the following Internet interfaces configured by default: dummy0, fe-cm-1 and
switch.0001. The default IP addresses for fe-cm-1 and switch.0001 are configured under the ip» {interface}»
ipv4, where {interface} is the name of the interface. The default switch.0001 interface is the VLAN interface and is
only seen if there is one or more Ethernet line modules installed. It is created implicitly, as all switched ports have
a default PVID of 1.
The following table lists the default IP addresses.
Interface IP Address
switch.0001 192.168.0.2/24
fe-cm-1 192.168.1.2/24
fe-em-1
a
192.168.2.1/24
a
Optional expansion module.
CONTENTS
Section3.2.1, “Configuring a Basic IPv4 Network”
Section3.2.2, “Configuring a Basic IPv6 Network”
Section3.2.1
Configuring a Basic IPv4 Network
To configure a basic IPv4 network, do the following:
1. Connect a computer to the Fast Ethernet (fe-cm-1) of the device and configure the computer to be on the
same subnet as the port.
2. Configure the computer to use the IPv4 address of the Fast Ethernet port as the default gateway.
3. Connect one of the switched ports from any available line module to a switch that is connected to a LAN.
4. Make sure the computer connected to the switch is on the same subnet as the switch.
5. Enable the Brute Force Attack (BFA) protection system on the device. For more information, refer to
Section6.3, “Enabling/Disabling Brute Force Attack Protection”.
6. Configure the switch and all the computers behind it to use switch.0001's IP address as the default gateway.
The default IP address is 192.168.0.2.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals