RUGGEDCOM ROX II
CLI User Guide
Chapter 17
Time Services
Viewing the Status of Reference Clocks 733
Tally Code Description
o This tally code indicates the peer is the system peer, but the synchronization distance is derived from a Pulse-
Per-Second (PPS) signal.
Section17.7
Viewing the Status of Reference Clocks
To view the status of reference clocks, type:
show services ntp status
A table similar to the following example appears:
ruggedcom# show services ntp status reference-clock
REFERENCE ADDRESS
ADDRESS STATE ID STRATUM TYPE WHEN POLL REACH DELAY OFFSET
JITTER
-------------------------------------------------------------------------------------------------------
127.127.1.0 System peer .LOCL. 10 l 2 64 377 0.000 0.000 0.000
206.186.255.227 Not synchronized .INIT. 16 - - 1024 0 0.000 0.000 0.000
206.186.255.226 Not synchronized .INIT. 16 - - 1024 0 0.000 0.000 0.000
142.3.100.2 Not synchronized .INIT. 16 - - 1024 0 0.000 0.000 0.000
This table provides the following information:
Parameter Description
address Synopsis:  A string 1 to 40 characters long
The IP address of the reference clock.
state Synopsis:  A string 1 to 32 characters long
The state of the clock.
reference-id Synopsis:  A string 1 to 40 characters long
The identification of the reference clock.
stratum Synopsis:  A string 1 to 32 characters long
The stratum number of the reference clock.
address-type Synopsis:  A string 1 to 32 characters long
The address type of the remote machine.
when Synopsis:  A string 1 to 32 characters long
The number of seconds since the last poll of the reference clock.
poll Synopsis:  A string 1 to 32 characters long
The polling interval in seconds.
reach Synopsis:  A string 1 to 32 characters long
An 8-bit left-rotating register. Any 1 bit means that a time packet was received.
delay Synopsis:  A string 1 to 32 characters long
The time delay (in milliseconds) to communicate with the reference clock.
offset Synopsis:  A string 1 to 32 characters long
The offset (in milliseconds) between our time and that of the reference clock.
jitter Synopsis:  A string 1 to 32 characters long

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals