Parameter Description
• no-lldp : The local LLDP agent can neither transmit nor receive LLDP frames.
• rxTx : The local LLDP agent can both transmit and receive LLDP frames through the
port.
• txOnly : The local LLDP agent can only transmit LLDP frames.
• rxOnly : The local LLDP agent can only receive LLDP frames.
notify Disabling notifications will prevent sending notifications and generating alarms for a
particular interface from the LLDP agent.
5. Add a VLAN ID (VID) for the port. For more information, refer to Section4.18.3.2, “Adding a VLAN to a
Routable Ethernet Port”.
6. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section4.18.3
Managing VLANs for Routable Ethernet Ports
This section describes how to manage VLANs for routable Ethernet ports.
CONTENTS
• Section4.18.3.1, “Viewing a List of VLANs for Routable Ethernet Ports”
• Section4.18.3.2, “Adding a VLAN to a Routable Ethernet Port”
• Section4.18.3.3, “Deleting a VLAN for a Routable Ethernet Port”
Section4.18.3.1
Viewing a List of VLANs for Routable Ethernet Ports
To view a list of VLANs configured for either a routable Ethernet port or virtual switch, type:
show running-config interface interface vlan
Where:
• interface is the type of interface
If VLANs have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config interface eth vlan | tab
IP
ADDRESS ON
SLOT PORT VID SRC DEMAND QOS INGRESS MARK
------------------------------------------------------
cm 1
999 static -
!
If no VLANs have been configured, add VLANs as needed. For more information about configuring VLANs for
either a routable Ethernet port or virtual switch, refer to Section4.18.3.2, “Adding a VLAN to a Routable Ethernet