EasyManuals Logo
Home>Siemens>Network Hardware>RUGGEDCOM ROX II

Siemens RUGGEDCOM ROX II User Manual

Siemens RUGGEDCOM ROX II
798 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #396 background imageLoading...
Page #396 background image
Chapter 10
Serial Server
RUGGEDCOM ROX II
CLI User Guide
350 Adding a Local Host
If no local hosts have been configured, add hosts as needed. For more information, refer to Section10.6.2,
“Adding a Local Host”.
Section10.6.2
Adding a Local Host
To add a local host for a serial port using the raw socket protocol, do the following:
NOTE
A maximum of two multicast local host entries are permitted per serial interface.
1. Make sure the CLI is in Configuration mode.
2. Add the local host by typing:
interface serial slot port protocols rawsocket setrawsocket local-host address
Where:
slot is the name of the module location
port is the port number (or a list of ports, if aggregated in a port trunk) for the module
address is a multicast group IP address for which the interface is a sink
NOTE
When a local host is added, either loopback must be enabled or a local host interface must be
added.
3. If a local host interface is required, proceed to Step 4. Otherwise, select Loopback to enable the local host to
receive data from a loopback interface.
The loopback interface must have the same source multicast group IP address and local port number as the
serial port. A matching remote host with loopback enabled must also be configured.
4. [Optional] Add a local host interface. For more information, refer to Section10.8.2, “Adding a Local Host
Interface”.
5. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section10.6.3
Deleting a Local Host
To delete a local host, do the following:
1. Make sure the CLI is in Configuration mode.
2. Delete the local host by typing:
no interface serial slot port protocols rawsocket setrawsocket local-host address local-port
Where:
slot is the name of the module location
port is the port number (or a list of ports, if aggregated in a port trunk) for the module
address is the IP address for the local host

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals