EasyManuals Logo
Home>Siemens>Network Hardware>RUGGEDCOM ROX II

Siemens RUGGEDCOM ROX II User Manual

Siemens RUGGEDCOM ROX II
798 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #666 background imageLoading...
Page #666 background image
Chapter 14
Network Redundancy
RUGGEDCOM ROX II
CLI User Guide
620 Managing Link Failover Protection
Parameter Description
name Synopsis:  A string
The conn-sync dedicated link interface name.
state Synopsis:  A string
The conn-sync dedicated link status.
role Synopsis:  A string
The conn-sync dedicated link role.
byte-sent Synopsis:  A 64-bit unsigned integer
The number of bytes sent on conn-sync dedicated link.
byte-received Synopsis:  A 64-bit unsigned integer
The number of bytes received on conn-sync dedicated link.
packet-sent Synopsis:  A 64-bit unsigned integer
The number of packets sent on conn-sync dedicated link.
packet-received Synopsis:  A 64-bit unsigned integer
The number of packets received on conn-sync dedicated link.
error-sent Synopsis:  A 64-bit unsigned integer
The number of errors sent on conn-sync dedicated link.
error-received Synopsis:  A 64-bit unsigned integer
The number of errors received on conn-sync dedicated link.
Section14.2
Managing Link Failover Protection
Link failover provides an easily configurable means of raising a backup link upon the failure of a designated main
link. The main and backup links can only be Ethernet.
Link failover can back up to multiple remote locations, managing multiple main-to-backup link relationships.
Link failover can also be used to migrate the default route from the main link to the backup link.
The time after a main link failure to backup link startup, and the time after a main link recovery to backup link
stoppage, are configurable. The link failover function also provides failover status information and a test of the
failover settings.
CONTENTS
Section14.2.1, “Viewing the Link Failover Log”
Section14.2.2, “Viewing the Link Failover Status”
Section14.2.3, “Managing Link Failover Parameters”
Section14.2.4, “Managing Link Failover Backup Interfaces”
Section14.2.5, “Managing Link Failover Ping Targets”
Section14.2.6, “Testing Link Failover”
Section14.2.7, “Canceling a Link Failover Test”

Table of Contents