Chapter 8
Layer 2
RUGGEDCOM ROX II
CLI User Guide
268 Configuring a Switched Ethernet Port
switch lm1 1
auton on
speed auto
duplex auto
switchport
no flow-control
no alias
rate-limiting
no ingress-limit
no egress-limit
!
port-security
no shutdown-time
no admin-shutdown
dot1x
no reauth-enable
!
!
lldp
no notify
!
mcast-filtering
no gmrp
!
cos
no inspect-tos
!
vlan
pvid 1
no gvrp-mode
!
spanning-tree
no restricted-role
no restricted-tcn
!
!
.
.
.
Section8.1.2
Configuring a Switched Ethernet Port
To configure a switched Ethernet port, do the following:
1. Make sure the CLI is in Configuration mode.
2. Navigate to interface» switch» {slot}» {port}, where {slot} is the module and {port} is the switched
Ethernet port.
3. Configure the port settings by configuring the following parameter(s) as required:
CAUTION!
Security hazard – risk of unauthorized access and/or exploitation. Switched Ethernet ports are
enabled by default. It is recommended that ports that are not in use be disabled. Unused ports, if
not configured properly, could potentially be used to gain access to the network behind the device.
CAUTION!
Configuration hazard – risk of data corruption. Changing a switched Ethernet port from switchport
mode to dedicated routing mode will automatically change any configuration elements that

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals