RUGGEDCOM ROX II
CLI User Guide
Chapter 12
Tunneling and VPNs
Adding a GRE Tunnel 401
Section12.7.3
Adding a GRE Tunnel
To add a GRE tunnel, do the following:
1. Make sure the CLI is in Configuration mode.
2. Add the GRE tunnel by typing:
tunnel gre name
Where:
name is the interface name of the GRE tunnel network. The interface name must start with a lowercase
letter, but may contain any combination of lowercase letters, numbers and dashes up to a maximum of 10
characters. The prefix gre- will be added to this interface name.
3. Configure the following parameter(s) as required:
Parameter Description
local-ip { local-ip } Synopsis:  A string 7 to 15 characters long or a string 6 to 40 characters long
The IP address of the local end of the tunnel.
This parameter is mandatory.
remote-ip { remote-ip } Synopsis:  A string 7 to 15 characters long or a string 6 to 40 characters long
The IP address of the remote end of the tunnel.
This parameter is mandatory.
remote-net { remote-net } Synopsis:  A string 9 to 18 characters long or a string 4 to 43 characters long
The target network of remote end of the tunnel.
mtu { mtu } Synopsis:  A 32-bit signed integer
Default:  1476
The MTU of the GRE interface.
multicast Enables multicast traffic on the tunnel interface.
cost { cost } Synopsis:  A 32-bit signed integer between 1 and 255
Default:  1
The routing cost associated with networking routing that directs traffic through the
tunnel.
key { key } Synopsis:  { none, input, output, both }
Default:  none
The key for tunneled packets
key-id { key-id } Synopsis:  A 32-bit unsigned integer between 0 and 4294967295
Default:  0
The key ID for tunneled packets
checksum { checksum } Synopsis:  { none, input, output, both }
Default:  none
The checksum for tunneled packets
sequence { sequence } Synopsis:  { none, input, output, both }
Default:  none
The sequence number for tunneled packets
tunnel-alarms Synopsis:  { true, false }
Default:  false

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals