RUGGEDCOM ROX II
CLI User Guide
Chapter 13
Unicast and Multicast Routing
Setting the Device as an RP Candidate 595
Section13.14.6
Setting the Device as an RP Candidate
To set the device as an RP candidate, do the following:
1. Make sure the CLI is in Configuration mode.
2. Set the device as an RP candidate by typing:
routing multicast dynamic pim-sm rp-candidate local-address address timer timer priority number
Where:
address is the local address to be used in the Cand-RP messages. If not specified, the largest local IP
address will be used (excluding passive interfaces).
timer is the number of seconds to wait between advertising and Cand-RP message.
priority sets the priority for this CRP. Smaller values have higher priority.
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section13.14.7
Managing PIM-SM Interfaces
PIM-SM requires at least one interface on which to receive or transmit advertisements. The interface must be non-
passive and be assigned an IP address.
CONTENTS
Section13.14.7.1, “Viewing a List of PIM-SM Interfaces”
Section13.14.7.2, “Enabling/Disabling a PIM-SM Interface”
Section13.14.7.1
Viewing a List of PIM-SM Interfaces
1. Make sure the CLI is in Configuration mode.
2. Navigate to routing» multicast» dynamic» pim-sm and press Enter.
3. At the command prompt, type show full-configuration and press Enter.The PIM-SM interfaces
information appears:
ruggedcom(config-pim-sm)# show full-configuration | tab
routing multicast dynamic pim-sm
enabled
bsr-candidate local-address 1.1.1.1
bsr-candidate priority 1
rp-candidate local-address 1.1.1.1
rp-candidate priority 1
no broken-cisco-checksum
interface
IFNAME PASSIVE
----------------------
dummy0 false
fe-1-1 false
fe-1-16 false
fe-cm-1 true

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals