RUGGEDCOM ROX II
CLI User Guide
Chapter 8
Layer 2
Clearing Switched Ethernet Port Statistics 277
Parameter Description
The number of received and transmitted packets with size of 512 to 1023 octets. This
includes received and transmitted packets as well as dropped and local received packets. This
does not include rejected received packets
This parameter is mandatory.
pkts-1024to1518-octets Synopsis: A 32-bit unsigned integer
The number of received and transmitted packets with a size of 1024 to 1536 octets. This
includes received and transmitted packets as well as dropped and local received packets. This
does not include rejected received packets.
This parameter is mandatory.
Section8.1.6
Clearing Switched Ethernet Port Statistics
To clear the statistics collected for a specific switched Ethernet port, type:
interfaces switch slot port clear-port-stats
Where:
• slot is the name of the module location
• port is the port number (or a list of ports, if aggregated in a port trunk) for the module
Section8.1.7
Resetting a Switched Ethernet Port
To reset a switched Ethernet port, type:
interfaces switch slot port reset-port
Where:
• slot is the name of the module location
• port is the port number (or a list of ports, if aggregated in a port trunk) for the module
Section8.1.8
Testing Switched Ethernet Port Cables
Diagnostics can be performed on switched Ethernet port cables to assess their overall quality.
CONTENTS
• Section8.1.8.1, “Running a Cable Diagnostic Test”
• Section8.1.8.2, “Viewing Cable Diagnostic Statistics”
• Section8.1.8.3, “Clearing Cable Diagnostic Statistics”