This list provides the following information:
Parameter Description
running Synopsis: { true, false }
Whether or not a cable test is currently running on this port
This parameter is mandatory.
good Synopsis: A 16-bit unsigned integer
The number of times GOOD TERMINATION (no fault) is detected on the cable pairs of the
selected port.
This parameter is mandatory.
open Synopsis: A 16-bit unsigned integer
The number of times OPEN is detected on the cable pairs of the selected port.
This parameter is mandatory.
short Synopsis: A 16-bit unsigned integer
The number of times SHORT is detected on the cable pairs of the selected port.
This parameter is mandatory.
imped Synopsis: A 16-bit unsigned integer
The number of times IMPEDANCE MISMATCH is detected on the cable pairs of the selected
port.
This parameter is mandatory.
pass-fail-total Synopsis: A string 1 to 19 characters long
This field summarizes the results of the cable diagnostics performed so far.
• Pass : the number of times cable diagnostics were successfully completed on the selected
port.
• Fail : the number of times cable diagnostics failed to complete on the selected port.
• Total : the total number of times cable diagnostics have been attempted on the selected
port.
This parameter is mandatory.
run-count Synopsis: A 16-bit unsigned integer
Run Count : The total number of iterations
This parameter is mandatory.
pass-count Synopsis: A 16-bit unsigned integer
Pass Count
This parameter is mandatory.
fail-count Synopsis: A 16-bit unsigned integer
Failure Count
This parameter is mandatory.
Section8.1.8.3
Clearing Cable Diagnostic Statistics
The following describes how to clear the statistics collected when cable diagnostic tests are performed. All of the