RUGGEDCOM ROX II
CLI User Guide
Chapter 15
Network Discovery and Management
Viewing Global Statistics and Advertised System
Information 665
Parameter Description
The delay in seconds between successive LLDP frame transmissions initiated by the value
or status changed. The recommended value is set by the following formula: 1 is less than
or equal to txDelay less than or equal to (0.25 * Tx Interval)
notification-interval { notification-interval } Synopsis:  A 32-bit signed integer between 5 and 3600
Default:  5
Controls transmission of LLDP traps. The agent must not generate more than one trap in
an indicated period.
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section15.1.2
Viewing Global Statistics and Advertised System Information
To view global statistics for LLDP, type:
show switch net-discovery lldp global-statistics
A table or list similar to the following appears:
ruggedcom# show switch net-discovery lldp global-statistics
global-statistics
inserts 21
deletes 20
drops 0
ageouts 8
last change time 3D14m19s
This table or list displays the following information:
Parameter Description
inserts Synopsis:  A 32-bit unsigned integer between 0 and 4294967295
The number of times an entry was inserted into the LLDP Neighbor Information Table.
This parameter is mandatory.
deletes Synopsis:  A 32-bit unsigned integer between 0 and 4294967295
The number of times an entry was deleted from the LLDP Neighbor Information Table.
This parameter is mandatory.
drops Synopsis:  A 32-bit unsigned integer between 0 and 4294967295
The number of times an entry was deleted from the LLDP Neighbor Information Table
because the information timeliness interval has expired.
This parameter is mandatory.
ageouts Synopsis:  A 32-bit unsigned integer between 0 and 4294967295
The number of all TLVs discarded.
This parameter is mandatory.
last-change-time Synopsis:  A string
The duration of time between power-on and when this information was received.
This parameter is mandatory.
To view the system information that is advertised to neighbors, type:
show switch net-discovery lldp local-system

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals