RUGGEDCOM ROX II
CLI User Guide
Chapter 10
Serial Server
Managing Remote Hosts 347
loopback true
For more information, refer to Section10.6.2, “Adding a Local Host”
13. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
14. Verify the configuration by typing the following:
traceserial
Final Configuration Example
Serial Port 1 Configuration
serial lm1 1
no alias
protocols rawsocket
setrawsocket local-port 10001
setrawsocket transport udp
setrawsocket remote-host 232.1.1.1 5001
loopback true
interface switch.0010
!
interface switch.0020
Serial Port 2 Configuration
serial lm1 2
no alias
protocols rawsocket
setrawsocket local-port 5001
setrawsocket transport udp
setrawsocket local-host 232.1.1.1
loopback true
Section10.5
Managing Remote Hosts
Remote hosts are required when the UDP transport connection protocol is selected for the raw socket protocol.
CONTENTS
Section10.5.1, “Viewing a List of Remote Hosts”
Section10.5.2, “Adding a Remote Host”
Section10.5.3, “Deleting a Remote Host”
Section10.5.1
Viewing a List of Remote Hosts
To view a list of remote hosts configured for a serial port using the raw socket protocol, type:
show running-config interface serial protocols rawsocket setrawsocket remote-host
If hosts have been configured, a table or list similar to the following example appears:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals