RUGGEDCOM ROX II
CLI User Guide
Chapter 8
Layer 2
Managing Forbidden Ports 313
Where:
id is the ID of the VLAN
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section8.5.6
Managing Forbidden Ports
Static VLANs can be configured to exclude ports from membership in the VLAN using the forbidden ports list.
CONTENTS
Section8.5.6.1, “Viewing a List of Forbidden Ports”
Section8.5.6.2, “Adding a Forbidden Port”
Section8.5.6.3, “Deleting a Forbidden Port”
Section8.5.6.1
Viewing a List of Forbidden Ports
To view a list of forbidden ports, type:
show running-config switch vlans static-vlan forbidden-ports
If ports have been forbidden, a table or list similar to the following example appears:
ruggedcom# show running-config switch vlans static-vlan forbidden-ports | tab
VID SLOT PORT
-----------------
50
lm1 1
lm1 2
60
lm1 2
lm1 3
lm1 4
70
lm1 5
!
If no ports have been forbidden, add forbidden ports as needed. For more information, refer to Section8.5.6.2,
“Adding a Forbidden Port”.
Section8.5.6.2
Adding a Forbidden Port
To add a forbidden port, do the following:
1. Make sure the CLI is in Configuration mode.
2. Add the forbidden port by typing:
switch vlans static-vlan name forbidden-ports slot port

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals