Chapter 14
Network Redundancy
Enabling/Disabling Connection Synchronization 617
IMPORTANT!
Well-formed stateful firewall rules are required. For more information, refer to Section6.9.1.1,
“Stateless vs. Stateful Firewalls”.
1. Configure a firewall with stateful firewall rules to control inbound and outbound traffic. For more
information, refer to Section6.9.3, “Adding a Firewall”.
2. Make sure the VRRP service is enabled. For more information, refer to Section14.1.3, “Enabling/Disabling
VRRP”.
3. Configure VRRP instances and groups. For more information, refer to Section14.1.6.2, “Adding a VRRP
Instance” and Section14.1.5.2, “Adding a VRRP Group”.
4. Define one or more dedicated links for each VRRP group. For more information, refer to Section14.1.10.4,
“Adding a Dedicated Link”.
5. Select a link to be the default dedicated link for any VRRP group not assigned a dedicated link. For more
information, refer to Section14.1.10.6, “Selecting a Default Dedicated Link”.
6. Enable the configuration synchronization service. For more information, refer to Section14.1.10.2, “Enabling/
Disabling Connection Synchronization”.
Once the configuration is complete, verify the status of the service on both devices. For more information, refer to
Section14.1.10.7, “Viewing the Status of Each Dedicated Link”.
Section14.1.10.2
Enabling/Disabling Connection Synchronization
To enable or disable connection synchronization, do the following:
1. Make sure the CLI is in Configuration mode.
2. Enable or disable connection synchronization by typing:
Enabling
services conn-sync enabled
Disabling
no services conn-sync enabled
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section14.1.10.3
Viewing a List of Dedicated LInks
To view a list of dedicated links, type:
show running-config services conn-sync dedicated-link | tab
If dedicated links have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config services conn-sync dedicated-link | tab
SEND RECV
NAME INTERFACE IP MCAST IP GROUP BUFFER BUFFER
---------------------------------------------------------------
3 fe-2-3 100.0.5.1 225.0.0.51 3781 1220 1220
4 fe-2-4 100.1.5.1 225.0.0.52 3782 1220 1220

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals