CLI User Guide
672 Enabling and Configuring SNMP Sessions
Standard MIB Trap and Description
RFC 3895 DS1-MIB ds1LineStatusChange
A ds1LineStatusChange trap is sent when the status of a dsx1Line instance
changes. The value of the trap is the value of one or more of the following
instances:
dsx1RcvFarEndLOF – Far end Loss of Frames (i.e. yellow alarm or RAI)
dsx1RcvAIS – Far end sending AIS
dsx1LossOfFrame – Near end Loss of Frame (i.e. red alarm)
dsx1LossofSignal – Near end Loss of Signal
dsx1OtherFailure – Out of Frame
dsx1NoAlarm
Section15.2.2
Enabling and Configuring SNMP Sessions
To enable and configure SNMP sessions, do the following:
1. Make sure the CLI is in Configuration mode.
2. Navigate to admin» snmp and configure the following parameter(s) as required:
IMPORTANT!
To generate all SNMP traffic for a specific interface, make sure the IP address for the desired
interface is set for both the Listen IP and Source IP for Traps parameters.
Parameter Description
enabled Synopsis:  { true, false }
Default:  false
Provides the ability to configure SNMP features on the device.
listen-ip { listen-ip } Synopsis:  A string
Default:  0.0.0.0
The IP Address the SNMP agent will listen on for SNMP requests.
port { port } Synopsis:  A 16-bit unsigned integer between 0 and 65535
Default:  161
The port the SNMP agent will listen on for SNMP requests.
extra-ip-ports { extra-ip-ports } Synopsis:  A string
The SNMP agent will also listen on these IP Addresses. For port values, add ':#' to set the
non-default port value. (ie. xxx.xxx.xxx.xxx:19343 [::] [::]:16000). If using the default
address, do not specify another listen address with the same port.
max-sessions { max-sessions } Synopsis:  a 32-bit unsigned integer
Default:  30
The maximum number of concurrent SNMP sessions.
snmp-engine-id { snmp-engine-id } Synopsis:  A string
Provides specific identification for the engine/device. By default, this value is set to use
the base MAC address within the Engine ID value.
When using SNMPv3: If you change this value, you must also change the User SNMP
Engine ID value for SNMP users.
source-ip { source-ip } Synopsis:  A string

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals