CLI User Guide
Chapter 2
Using RUGGEDCOM ROX II
Configuration Mode General Commands 41
Parameter Description
the device will continue to be blocked from making changes until the session
timeout period expires.
Section2.5.10.5
Configuration Mode General Commands
Configuration mode provides a set of general commands that allow users to work with configuration data.
Parameter Description
abort
Exits the configuration session without saving changes.
NOTE
In an edit exclusive session, any pending unconfirmed commits will not be
canceled until their timeout periods expire. A new edit exclusive session cannot
be opened until the timeout period ends.
clear
Deletes all configuration changes.
commit no-confirm
Immediately commits the current set of configuration changes. This command will prompt
the user to confirm the action. Use the no-confirm parameter to revert the configuration
without requiring confirmation.
commit abort
In an edit exclusive session, this command aborts/cancels all confirmed commits.
commit and-quit
Commits all confirmed and unconfirmed changes and exits the configuration mode.
commit check
Validates the current configuration.
commit confirmed timeout
Temporarily commits changes for a period of time, allowing users to test the configuration
before fully committing the changes. The changes must be committed using a standard
commit command before the timeout period ends. If changes are not committed before the
timeout period ends, they are automatically discarded and the previous settings are restored.
A timeout period can be specified at the end of the command. The default timeout period is
10 minutes. The minimum timeout period is 1 minute. For example:
ruggedcom(config-admin)# commit confirmed 2
To cancel a commit before the time elapses and discard the changes, type:
commit abort
To permanently commit the changes before the time elapses, type:
commit
commit comment text
Immediately commits the current set of configuration changes along with a custom
comment. The comment will appear next to the commit in a list of pending of commits.
commit label text
Immediately commits the current set of configuration changes along with a custom label. In
a list of pending commits, the label will appear instead of the auto-generated commit ID.
commit persist-id text
Immediately commits the current set of configuration changes and assigns a user-specified
ID or flag.
commit save-running file
Immediately commits the current set of configuration changes and saves them to the
specified file. It does not save the complete running configuration.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals