40 Administration Commands
Parameter Description
admin shutdown
Shuts down the device.
For more information on shutting down the device, refer to Section4.4, “Shutting Down the
Device”
admin software-upgrade decline-
upgrade
Cancels (or declines) a recent software upgrade that is waiting for a reboot to the upgraded
partition.
admin software-upgrade launch-
upgrade
Launches an upgrade in the alternate partition.
admin software-upgrade rollback-
reboot
Boots to a previous software release on the alternate partition.
maint-login
CAUTION!
Configuration hazard – risk of data loss/corruption. Maintenance mode is
provided for troubleshooting purposes and should only be used by Siemens
Canada Ltd technicians. Maintenance mode is provided for troubleshooting
purposes and all possible commands are not documented. Misuse of
maintenance mode commands can corrupt the operational state of the device
and render the device inaccessible.
Logs in to the underlying operating system as the root user. The user must be an
administrator and be able to provide the maint-login password.
monitor start filename
Starts displaying the specified system log or tracing the specified file. If necessary, the output
can be redirected to a file. For information on how to redirect output, refer to Section2.5.6,
“Using Output Redirects”. Use auto completion to view a list of available logs and files.
monitor stop filename
Stops displaying the specified system log or tracing the specified file. Use auto completion to
view a list of available logs and files.
reportstats
Displays an extensive collection of device-specific statistics. If necessary, the output can be
redirected to a file. For information on how to redirect output, refer to Section2.5.6, “Using
Output Redirects”.
config private
Enters a configuration mode where users can make changes to the system. This is
the primary mode for most users who want to make changes to the device/network
configuration. It can be accessed by multiple Operator and Admin users.
All changes made during a private configuration session are hidden from other users until
they are committed. Each change must be committed before it is applied to the active
system.
If a user opens an exclusive configuration session during another user's private configuration
session, the user in the private configuration session cannot commit their changes until the
other user ends their session.
config exclusive
Enters a configuration mode where users can make changes to the system. This mode
is similar to the private configuration mode, except all other users are blocked from
committing their changes until the user using the exclusive configuration mode exits. Only
one Operator or Admin user can use the exclusive configuration mode at a time per device.
When committing changes in exclusive configuration mode, use the confirmed option
to set a timeout period. Changes will be applied for the set period of time, after which
the configuration will be reset to its previous settings. This allows users to test their
configuration changes before fully applying them to the active system.
For more information about the confirmed option, refer to Section2.5.10.5, “Configuration
Mode General Commands”.
IMPORTANT!
Always log out of the exclusive configuration mode or exit the transaction. If
the session is terminated before a user exits properly, other users logged in to

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals