Chapter 6
Security
RUGGEDCOM ROX II
CLI User Guide
128 Enabling/Disabling Compact Flash Card Removal Detection
NOTE
For information about how to view auth.log, refer to Section4.10.1, “Viewing Logs”.
When the default alarm for brute force attacks is enabled, a host that exceeds the maximum number of failed
login attempts will trigger an alarm. The alarm will be listed on the list of active alarms until the alarm is resolved
and acknowledged.
ruggedcom# show admin alarms active-alarms | tab
ALARM EVENT
SUBSYSTEM ID ID SEVERITY DESCRIPTION
--------------------------------------------------------------------------------
security 2 1 alert BFA from IP 172.30.151.141 is blocked
To enable/disable the BFA protection mechanism, do the following:
1. Make sure the CLI is in Configuration mode.
2. Enable the BFA protection mechanism by typing:
security bruteforce enabled
Or disable the BFA protection mechanism by typing:
no security bruteforce enabled
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4. [Optional] Enable or disable the default alarm for brute force attacks. For more information, refer to
Section5.7.4, “Configuring an Alarm”.
Section6.4
Enabling/Disabling Compact Flash Card Removal
Detection
RUGGEDCOM ROX II features a detection mechanism to notify users when the compact flash card is removed
during operation. When enabled, the system will immediately reboot and generate a failsafe alarm when the card
is removed.
This feature is disabled by default.
To enable/disable the compact flash card removal detection mechanism, do the following:
1. Make sure the CLI is in Configuration mode.
2. Enable the compact flash card removal detection mechanism by typing:
security cfdetect enabled
Or disable the BFA protection mechanism by typing:
no security cfdetect enabled
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals