RUGGEDCOM ROX II
CLI User Guide
Chapter 6
Security
Configuring RADIUS Authentication for Switched Ethernet
Ports 141
Parameter Description
The IPv4 address of the server.
port-udp { port-udp } Synopsis:  A 32-bit signed integer between 1 and 65535
Default:  1812
password { password } Synopsis:  A string
4. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section6.7.3.3
Configuring RADIUS Authentication for Switched Ethernet Ports
To configure RADIUS authentication for switched Ethernet ports, do the following:
IMPORTANT!
Passwords are case-sensitive.
1. Make sure the CLI is in Configuration mode.
2. Type the following:
switch port-security radius
3. Configure the primary or secondary RADIUS server by typing either primary or secondary and configuring
the following parameter(s) as required:
Parameter Description
address { address } Synopsis:  A string 7 to 15 characters long
The IPv4 address of the server.
port-udp { port-udp } Synopsis:  A 32-bit signed integer between 1 and 65535
Default:  1812
The IPv4 port of the server.
password { password } Synopsis:  A string
The password of the server
4. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section6.7.4
Configuring TACACS+ Authentication
TACACS+ (Terminal Access Controller Access-Control System Plus) is a TCP-based protocol which provides access
control for routers, network access servers and other networked computing devices via one or more centralized
servers. TACACS+ provides separate authentication, authorization and accounting services.
Primary and secondary TACACS+ servers, typically operating from a common database, can be configured for
redundancy. If the first server does not respond to an authentication request, the request will be forwarded to the
second server until a positive/negate acknowledgment is received.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals