Chapter 13
Unicast and Multicast Routing
RUGGEDCOM ROX II
CLI User Guide
450 Configuring an Interface
Section13.6.6.2
Configuring an Interface
When IS-IS is enabled, two interfaces are already configured: fe-cm-01 and switch.0001.
To configure optional parameters for these and any other interfaces that have been added for IS-IS, do the
following:
1. Make sure the CLI is in Configuration mode.
2. Navigate to the interface by typing:
routing isis interface name
Where:
name is the name of the interface. If the desired interface is not available, it must be created as a VLAN. For
more information about creating a VLAN, refer to Section8.5, “Managing VLANs”.
3. Configure the following parameter(s) as required:
Parameter Description
{ ifname } Synopsis:  A string
Interface name.
ipv4-area-tag { ipv4-area-tag } Synopsis:  A string
Name of Area Tag to be used for IS-IS over IPv4.
circuit-type { circuit-type } Synopsis:  { level-1-only, level-2-only, level-1-2 }
The IS-IS Circuit Type. Level-1 routers have neighbors only on the same area. Level-2
(backbone) can have neighbors on different areas. Level-1-2 can have neighbors on any
areas. Default is level-1-2.
point-to-point Synopsis:  { true, false }
Default:  false
Enable or disable point-to-point network communication
passive Synopsis:  { true, false }
Default:  true
Whether an interface is active or passive. Passive interfaces do not send packets to other
routers and are not part of an IS-IS area.
circuit-password { circuit-password } Synopsis:  A string 1 to 254 characters long
The value to be used as a transmit password in IIH PDUs transmitted by this Intermediate
System.
circuit-authorization { circuit-
authorization }
Synopsis:  { clear, md5 }
Default:  clear
The authorization type ot be associated with the transmit password in IIH PDUs
transmitted by this Intermediate System.
metric { metric } Synopsis:  A 32-bit signed integer between 1 and 16777214
Default:  10
Metric assigned to the link, used to calculate the cost of the route. Value ranges from 1
to 16777214. Default is 10.
csnp-interval { csnp-interval } Synopsis:  A 16-bit unsigned integer between 1 and 600
Default:  10
CSNP interval in seconds, ranging from 1 to 600. Default is 10.
hello-interval { hello-interval } Synopsis:  A 16-bit unsigned integer between 1 and 600
Default:  3