RUGGEDCOM ROX II
CLI User Guide
Chapter 15
Network Discovery and Management
Viewing Statistics for SNMP 673
Parameter Description
If set, all traffic/traps originating from this device shall use the configured IP Address for
the Source IP.
auth-failure-trap-notify { auth-failure-trap-
notify }
Synopsis:  { none, snmpv1_trap, snmpv2_trap, snmpv2_inform, snmpv3_trap,
snmpv3_inform }
Default:  none
When the SNMP agent sends the standard authenticationFailure notification,
it is delivered to the management targets defined for the snmpNotifyName
in the snmpNotifyTable in SNMP-NOTIFICATION-MIB (RFC3413). If
authenticationFailureNotifyName is the empty string (default), the notification is
delivered to all management targets.
authen-traps-enabled Synopsis:  { true, false }
Default:  false
Enables authentication traps to be sent from the SNMP agent.
dscp { dscp } Synopsis:  An 8-bit unsigned integer between 0 and 63
Default:  0
Support for setting the Differentiated Services Code Point (6 bits) for traffic originating
from the SNMP agent.
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section15.2.3
Viewing Statistics for SNMP
To view the statistics collected for SNMP, type:
show admin snmp statistics
If statistics are available, a table or list similar to the following example appears:
ruggedcom# show admin snmp statistics
statistics
unsupported sec levels 1
not in time windows 1
unknown user names 1
unknown engine ids 4
wrong digests 1
decryption errors 1
This table or list provides the following information:
Parameter Description
unsupported-sec-levels Synopsis:  A 32-bit unsigned integer
The total number of packets received by the SNMP engine which were dropped because they
requested a securityLevel that was unknown to the SNMP engine or otherwise unavailable.
This parameter is mandatory.
not-in-time-windows Synopsis:  A 32-bit unsigned integer
The total number of packets received by the SNMP engine which were dropped because they
appeared outside of the authoritative SNMP engine's window.
This parameter is mandatory.
unknown-user-names Synopsis:  A 32-bit unsigned integer
The total number of packets received by the SNMP engine which were dropped because they
referenced a user that was not known to the SNMP engine.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals