RUGGEDCOM ROX II
CLI User Guide
Chapter 8
Layer 2
Configuring a Switched Ethernet Port 269
depended on it and potentially invalidate parts of the device configuration. For example, if a
switched Ethernet port is a trunk port, changing it to dedicated routing mode will automatically
remove it from the trunk and, therefore, make the trunk invalid. A trunk must consist of two trunk
ports.
NOTE
Switched Ethernet ports in dedicated routing port mode cannot be trunk ports.
NOTE
The configuration for a switched Ethernet port in switchport mode can be restored when it is
removed from a trunk. However, the configuration cannot be restored if the port is in dedicated
routing mode.
Parameter Description
enabled Synopsis:  { true, false }
Default:  true
Provides the option to enable or disable this interface. When unchecked(i.e disabled), the
interface will prevent all frames from being sent and received on that interface.
auton { auton } Synopsis:  A string
Enables or disables IEEE 802.3 auto-negotiation. Enabling auto-negotiation results in
speed and duplex being negotiated upon link detection; both end devices must be auto-
negotiation compliant for the best possible results.
This parameter is mandatory.
speed { speed } Synopsis:  A string
Speed (in megabits-per-second or gigabits-per-second). If auto-negotiation is enabled,
this is the speed capability advertised by the auto-negotiation process. If auto-
negotiation is disabled, the port is explicitly forced to this speed mode. AUTO means
advertise all supported speed modes.
This parameter is mandatory.
duplex { duplex } Synopsis:  A string
If auto-negotiation is enabled, this is the duplex capability advertised by the auto-
negotiation process. If auto-negotiation is disabled, the port is explicitly forced to this
duplex mode. AUTO means advertise all supported duplex modes.
This parameter is mandatory.
link-alarms Synopsis:  { true, false }
Default:  true
Disabling link-alarms will prevent alarms and LinkUp and LinkDown SNMP traps from
being sent for that interface. Link alarms may also be controlled for the whole system
under admin / alarm-cfg.
switchport Synopsis:  { true, false }
Sets the physical port into either switched mode or a dedicated routing mode.
flow-control Flow control is useful for preventing frame loss during times of severe network traffic
on-demand Bring up this interface on-demand only
ip-address-src { ip-address-src } Synopsis:  { static, dynamic }
Default:  static
Whether the IP address is static or dynamically assigned via DHCP or BOOTP. Option
DYNAMIC is a common case of a dynamically assigned IP address. It switches between
BOOTP and DHCP until it gets the response from the relevant server. This must be static
for non-management interfaces.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals