122 Adding a Scheduled Job
Parameter Description
The name of the scheduled job. The name can be up to 64 characters in length.
job-type { job-type } Synopsis:  { configchange, periodic }
Default:  periodic
Determines when to launch the scheduled job:
periodic: The job launches at a set date and time.
configchange: The job launches when the configuration changes.
job-minute { job-minute } Synopsis:  A string 1 to 128 characters long
Default:  0
For periodic jobs, sets the minutes portion of the job launch time. Valid values are in the
range of 0 to 59. If no value is set, the scheduler uses the default value of 0 and launches
the job every hour on the the hour.
To specify a single value, enter the value in the field. For example, to launch the job 10
minutes past the hour, enter 10.
To specify a list of values, enter the values as a comma-separated list. For example, to
launch the job at 15, 30, and 45 minutes past the hour, enter 15,30,45.
To specify a range of values, enter the range as comma-separated values. For example,
to launch the job every minute between 30 and 45 minutes past the hour, enter
30-45.
This parameter is not required for configchange jobs.
job-hour { job-hour } Synopsis:  A string 1 to 64 characters long
For periodic jobs, sets the hour portion of the job launch time, in the 24-hour clock
format. Valid values are in the range of 0 to 23. If no value is set, the job launches every
hour at the time set in the Minute field.
To specify a single value, enter the value in the field. For example, to launch the job at
5:00 pm, enter 17.
To specify a list of values, enter the values as a comma-separated list. For example, to
launch the job at 9:00 am, 12:00 pm, and 5:00 pm, enter 9,12,17.
To specify a range of values, enter the range as comma-separated values. For example,
to launch the job every hour between 9:00 am and 5:00 pm, enter 9-17.
This parameter is not required for configchange jobs.
job-day-month { job-day-month } Synopsis:  A string 1 to 64 characters long
For periodic jobs, sets the day of the month on which to run the scheduled job. Valid
values are in the range of 1 to 31. If no value is set, the job launches every day.
To specify a single value, enter the value in the field. For example, to launch the job on
the tenth day of the month, enter 10.
To specify a list of values, enter the values as a comma-separated list. For example, to
launch the job on the first, fifteenth, and thirtieth days of the month, enter 10,15,30.
To specify a range of values, enter the range as comma-separated values. For example,
to launch the job on days one through fifteen, enter 1-15.
This parameter is not required for configchange jobs.
job-month { job-month } Synopsis:  A string 1 to 32 characters long
For periodic jobs, sets the month in which to run the scheduled job. Valid values are in
the rage of 1 to 12. If no value is set, the job launches every day.
To specify a single value, enter the value in the field. For example, to set the month to
February, enter 2.
To specify a list of values, enter the values as a comma-separated list. For example, to
set the months to January, June, and December, enter 1,6,12.
To specify a range of values, enter the range as comma-separated values. For example,
to set the months to January through June, enter 1-6.
This parameter is not required for configchange jobs.
job-day-week { job-day-week } Synopsis:  A string 1 to 16 characters long

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals