Logged Security Events 17
Category Event Message Facility Severity
Event
Type
Log
audit user:
{Username}/0 Provided
Invalid Password
LOG_DAEMON Info Alarm Auth.logSE_ACCESS_DENIED
login failed,
reason='{Reason}', user
ipaddr='{IP Address}'
LOG_AUTHPRIV Notice Alarm Auth.log
ALARM: BFA from IP {IP
Address} is blocked ->
{Event Time}
LOG_DAEMON Emergency Alarm Syslog
{Function}: detect BFA
from {IP Address}, raise
alarm
LOG_DAEMON Verbose Alarm Syslog
SE_ACCOUNT_LOCKED_TEMP
{Function}: alarm
asserted id={Event ID}
LOG_DAEMON Verbose Alarm Syslog
SE_ACCOUNT_LOCKED_TEMP (Freed) {Function}: deassert BFA
alarm ip={IP address}
LOG_DAEMON Verbose Event Syslog
SE_AUDIT_LOG_CLEARED Deleted logs by restore-
factory-defaults issued
by user {Username}
LOG_DAEMON Emergency Alarm Syslog
SE_COMMUNICATION_DATA_INTEGRITY_ERROR FAILURE. The firmware
integrity check has
failed. This may indicate
that some operating
system files have been
modified or tampered
with. For assistance,
contact Siemens
Customer Support.
LOG_DAEMON Critical Alarm Syslog
SE_SESSION_CLOSED username:{Username}
usid:{User ID} stopped
{Context} session from
ip:{IP Address}
LOG_AUTH Notice Event Auth.log
SE_SESSION_CLOSED (console) username:{Username}
usid:{User ID} started
{Context} session from
ip: 127.0.0.1 source-
port:0 through console
protocol
LOG_AUTH Notice Event Auth.log
SE_PATCH_DEPLOYMENT_SUCCEEDED The other partition was
imaged successfully.
A reboot is required to
boot the other partition.
LOG_DAEMON Notice Event Upgrade
SE_PATCH_DEPLOYMENT_FAILED (Failure during
ROXFLASH)
A failure was
encountered in the
upgrade process.
LOG_DAEMON Notice Event Upgrade
SE_PATCH_DEPLOYMENT_FAILED (During uninstall -
ROXFLASH)
A failure was
encountered in the
uninstallation process.
LOG_DAEMON Notice Event Upgrade
SE_PATCH_DEPLOYMENT_FAILED (Can not connect
to upgrade server - ROXFLASH)
Failed to get upgrade
details from server,
please verify
connection.
LOG_DAEMON Notice Event Upgrade

Table of Contents