RUGGEDCOM ROX II
CLI User Guide
Chapter 15
Network Discovery and Management
Adding an SNMP Target Address 677
Parameter Description
A descriptive name for the target (ie. 'Corportate NMS').
enabled Synopsis:  { true, false }
Default:  true
Enables/disables this specific target.
target-address { target-address } Synopsis:  A string
An IPv4 or IPv6 address for the remote target.
This parameter is mandatory.
trap-port { trap-port } Synopsis:  A 16-bit unsigned integer between 0 and 65535
Default:  162
The UDP Port for the remote target to receive traps on.
security-model { security-model } Synopsis:  { v1, v2c, v3 }
Default:  v2c
The SNMP security model to use: SNMPv1, SNMPv2c, or USM/SNMPv3.
user-name { user-name } Synopsis:  A string
The user name to be used in communications with this target.
This parameter is mandatory.
security-level { security-level } Synopsis:  { noAuthNoPriv, authNoPriv, authPriv }
Default:  noAuthNoPriv
The SNMP security level:
authPriv: Communication with authentication and privacy.
authNoPriv: Communication with authentication and without privacy.
noAuthnoPriv: Communication without authentication and privacy.
control-community { control-community } Synopsis:  A string 1 to 32 characters long
Restricts incoming SNMP requests from the IPv4 or IPv6 address associated with this
community.
tag-list { tag-list } Synopsis:  { snmpv1_trap, snmpv2_trap, snmpv2_inform, snmpv3_trap,
snmpv3_inform }
Default:  snmpv2_trap
Selects the type of trap communications to be sent to this target.
NOTE
Multiple options can be selected.
inform-timeout { inform-timeout } Synopsis:  A 32-bit signed integer between 0 and 2147483647
Default:  6000
The timeout used for reliable inform transmissions (seconds*100).
inform-retries { inform-retries } Synopsis:  A 32-bit signed integer between 0 and 255
Default:  3
The number of retries used for reliable inform transmissions.
target-engine-id { target-engine-id } Synopsis:  A string
The target's SNMP local engine ID. This field may be left blank.
3. Type commit and press Enter to save the changes, or type revert and press Enter to abort.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals