4-7
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 4      Perform Node Acceptance Tests
NTP-G42 Perform the Terminal Node with 32WSS and 32DMX Cards Acceptance Test
Step 16 For Channel #1, change Operating Mode to Add Drop.
Step 17 Click Apply, then click Ye s .
Step 18 Click the Provisioning > Optical Chn > Parameters tabs.
Step 19 Verify that the actual power coming from the tunable laser or TXP_MR_2.5G card shown under the 
Power column is equal to the specified VOA Power Ref power shown in the same row.
Step 20 Click the Optical Line tab.
Step 21 Verify that the TX COM port (#67) has the same power as the VOA Power Ref setpoint in Step 19. This 
verifies that the optical signal is traveling correctly through the WSS card.
Step 22 Verify that the Port 1 power level reaches the provisioned VOA Power Ref setpoint.
Step 23 If an OPT-BST card is installed, complete the “DLP-G79 Verify the OPT-BST Amplifier Laser and 
Power” task on page 4-40 on the OPT-BST to ensure that the amplifier is working properly.
Step 24 Complete the “DLP-G80 Verify the OPT-PRE Amplifier Laser and Power” task on page 4-41 on the 
OPT-PRE to ensure that the amplifier is working properly.
Step 25 Complete the “DLP-G269 Verify the 32DMX-O Power” task on page 4-42 or “DLP-G270 Verify the 
32DMX Power” task on page 4-42 to verify that the 32DMX-O or 32DMX card is powered correctly.
Step 26 Display the 32WSS in card view.
Step 27 Click the Maintenance tab.
Step 28 For the circuit (channel) under test, click the Operating Mode table cell and choose Not Assigned from 
the drop-down list.
Step 29 Click Apply, then Yes .
Step 30 Click the Provisioning > Optical Chn: Optical Connector tabs.
Step 31 Click the Admin State table cell. Choose IS,AINS (ANSI) or Unlocked,AutomaticInService (ETSI) 
from the drop-down list for all ports that were changed to OOS,MT or Locked,Maintenance.
Step 32 Repeat Steps 7 through 31 for the remaining 31 wavelengths of the 100-Ghz grid to verify the correct 
behavior of all VOAs inside the 32WSS card.
Step 33 Restore the default administrative states to the OPT-BST, OPT-PRE, and 32DMX ports that were 
changed to OOS,MT (ANSI) or Locked,maintenance (ETSI) in Step 12. Remove the loopback created 
in Step 5.
Step 34 Complete the “NTP-G37 Run Automatic Node Setup” procedure on page 3-83 to restore the original 
configuration.
Step 35 Click the Alarms tab. 
a. Verify that the alarm filter is not on. See the “DLP-G128 Disable Alarm Filtering” task on page 8-28 
as necessary.
b. Verify that no equipment (EQPT) alarms appear indicating equipment failure or other hardware 
problems. If equipment failure alarms appear, investigate and resolve them before continuing. Refer 
to the Cisco ONS 15454 Troubleshooting Guide or the Cisco ONS 15454 SDH Troubleshooting 
Guide for procedures.
Stop. You have completed this procedure.